News - April 13, 2017
The Warren and Brown optical fibre ducting raceway is an Australian made solution for managing, routing and protecting fiber optic cords between termination equipment, patch panels and fibre optic splicing cabinets or frames. This cost-effective and reliable solution has been used in telecommunications exchanges, data centres, universities, hospitals, or anywhere fibre optic cabling is present.
The ducting raceway range keeps growing and evolving as new products were developed and introduced to the range.
ELBOW, 90O, M50 X 1.5
This 90o Elbow is typically used to feed an optical fibre cable into a cabinet after the cable has “broken-out” into several optical fibres. The Elbow is fastened to the cabinet using an M50 nut, after passing through a clearance hole. The lower end of the Elbow can accept either a 38mm dia. cable; or a Convoluted Tube, which houses the incoming optical fibre cable. The inner radius of the Elbow is 56mm, and the internal diameter is 41.5mm; so, the Elbow can typically accept a cable of around 37/38mm dia. Benefits & Features:
|
MOUNTING CLIP FOR METAL DUCTING FOR AN OVER THE TOP OUTLET:
A pair of plastic mounting clips enables an “Over the Top Outlet” to be located anywhere along a metal duct run. This enables optical fibre cords to leave the duct run at any position along its length, whilst maintaining the MBR at 30mm. The “Over the Top Outlet” allows 2.0mm dia. optical fibre cords to “drop-off” the duct run and feed into 100mm x 100mm (FR) plastic duct and components. The “Over the Top Outlet” is Part No: TC1279-307A; and is available separately.
Benefits & Features:
|
RACK TOP, DUCT FEEDING KIT, FOR A 1 METRE EQUIPMENT RACK
DATA RACK, FRONT TO BACK DUCT FOR FIBRE CORDS, WITH ELBOW OUTLETS
DATA RACK, FRONT TO BACK DUCT FOR FIBRE CORDS, WITH TRUMPET OUTLETS
This kit is installed from the front to the rear of a data rack, allowing fibre cords to be fed from front to back of the rack. The duct is supported by two sturdy metal mounting brackets fitted to the front and rear equipment mounting rails on either the left or right hand side; (4 x mounting screws and cage nuts are supplied). This kit occupies 2 RU of mounting space. The mounting brackets hold duct securing (“C”) brackets, which have 65mm of lateral adjustment. A length of 100mm x 50 mm duct carries the cords. It is supplied as a length of 800mm, which can be trimmed to suit the depth of the data rack. One end of the duct is slotted to accept a trumpet secured by a standard joiner. The other, (non-slotted), duct end is accurately cut to length and a trumpet is secured to the cut end of the duct using a slotless joiner. | |
|
Benefits & Features:
|
50MM TOP OUTLET VERTICAL DROP
It can be attached to our Yellow Duct, also to metal tray and wire mesh.
The Ducting Raceway range is backed up by our capabilities in network design, product support, training and with over 400 individual components in stock locally, so why use any other ducting raceway solution?