60083221195082

This 2RU, RH pivot open Splice/Patch Drawer accommodates up to 48 optical fibres. It features optical fibre cord management, that maintains the MBR at 35 mm radius throughout. At the rear of the drawer, an assembly of two, individually accessible, splice trays are provided. Each tray holds 24 fusion splices. Each splice tray has 2x12 fibre single splice protector holder clips (Part No: TC250S-13). Situated along the drawer are: 2 angled position patch panels, for 24 - simplex SC APC or SC UPC through adaptors. At the RHS drawer entry, a radius guide and two curved guides are provided to guarantee the MBR for optical fibre cord and loose tubes on entry and exit. Loose tubes are fed through guiding tubes to the trays RHS entry securing point, then onto the splice trays. Along the front face of the drawer, tie-off slots are provided for optical fibres cords. At the front of the Drawer a catch secured, hinged, record card system is provided. The entering and leaving optical fibre cord/s are either run straight into the RHS of the rack or around the rear of the drawers body to the LHS of the FTF. This 48 fibre, splice/patch drawer is typically used in Fibre Termination Frames. The drawer can be set up for either LH or RH pivot opening.

More Information
Fibre Capacity 48F
Size 2RU
  • Maintains fibre bending radius throughout, for terminated optical fibres at 35mm.
  • Supplied with 1 set of 2 high (2 x 24 fibre), splice tray assembly, for 48 fusion splices. 2x12 fibre splice protector clips
  • (Part No: TC250S-13) are provided on each splice tray. Used with a temporary splice tray holding bracket
  • Loose tubes are fed through guiding transport tubes to the trays RHS entry tie-off point, then onto the splice trays
  • Provides patching connection for up to 48 optical fibres, with SC APC or SC UPC connectors
  • Entry and exit fibre cords are guided by 35mm radius removable guides
  • An easily accessible, hinged, record system is provided in front of the patch panel
  • A guiding bracket for vertical optical fibre cords is recommended to be provided in the Rack; available separately
  • Through connectors have  ceramic, zirconia ferrule, insertion loss maximum 0.2dB and are capable of a reasonable number (e.g. 500) of matings/unmatings
  • Pigtails are supplied with a 0.9mm diameter optical fibre cord, set of 12 colours, 1.5 m long; 9 um core dia; 125 um cladding dia; and a 900 um tight buffered outer sheath. The cords withstand minimal tensile strength >100 N, with an MBR of 30mm. The connectors have zirconia ferrule 2.5mm diameter, insertion loss maximum of 0.2 dB, return loss minimum of 55 dB and are capable of a reasonable number (e.g. 500) of matings/unmatings
  • Operation temperature from -40° C to +85°C. Storage temperature from -40° C to +90°C.
  • Heat shrink splice protector’s length is 40mm or 60 mm; 3mm diameter; each sleeve has a stainless steel strength member; installed in 90 seconds.
  • Available with patch-only version P/N 60083223077082R or 60083223076082R
  • Purchase as a unit

Dimensions: 462//490 mm (W)(Body/Guides) x 85 mm (H) x 250/286 mm (D) (To Rails/O/A)

Weight: 5.3 kg