This high-density 1RU up to 96-fibre splice &/or patch shelf is loaded with 4 sub trays. Each sub tray can be equipped with 24 LC/APC or LC/UPC pigtails and 12 LC duplex adaptors. The shelf can accommodate max. 4 splice &/or patch trays with a total max. capacity of 96 LC connections.
The sub trays slide independently on side rails with a locking step at 40mm for patch management at the front. This provides excellent cable management and access to each row of connectors.
The outgoing patch cords are managed with an individual releasable cable management bracket, securing 24x patch cords per tray.
When installed in a chassis, each tray can slide out 40mm from home position, making patch cords installation easy, eliminating the need for pull-tab connectors.
Size | 1RU |
---|
Cable entry: Front and Rear
Application: Equipment racks - 600mm deep+
Part No. | RU | Fibre | Connectors | Description | ||
70063242004081R | 1RU | 96 | LC | Patch only | RH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC, Patch only, Right Hand, 19&21" mounting |
70063242003081L | 96 | LC | Patch only | LH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC, Patch only, Left Hand, 19&21" mounting | |
70063242002081R | 96 | LC/APC | Patch only | RH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC/A, Patch only, Right Hand, 19&21" mounting | |
70063242001081L | 96 | LC/APC | Patch only | LH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC/A, Patch only, Left Hand, 19&21" mounting | |
70063241018081L | 96 | LC/APC | Splice & Patch | LH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC/A, Splice & Patch, Left Hand, 19&21" mounting, all accessories | |
70063241019081R | 96 | LC/APC | Splice & Patch | RH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC/A, Splice & Patch, Right Hand, 19&21" mounting, all accessories | |
70063241028081L | 96 | LC | Splice & Patch | LH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC, Splice & Patch, Left Hand, 19&21" mounting, all accessories | |
70063241029081R | 96 | LC | Splice & Patch | RH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC, Splice & Patch, Right Hand, 19&21" mounting, all accessories | |
70063241038081L | 72 | LC | Splice & Patch | LH | 1RU UHD Fibre Optic Patch Panel, 72 Fibres, LC, Splice & Patch, Left Hand, 19&21" mounting, all accessories | |
70063241036081L | 48 | LC | Splice & Patch | LH | 1RU UHD Fibre Optic Patch Panel, 48 Fibres, LC, Splice & Patch, Left Hand, 19&21" mounting, all accessories | |
70063241024081L | 48 | SC/APC | Splice & Patch | LH | 1RU UHD Fibre Optic Patch Panel, 48 Fibres, SC/A, Splice & Patch, Left Hand, 19&21" mounting, all accessories | |
70063241025081R | 48 | SC/APC | Splice & Patch | RH | 1RU UHD Fibre Optic Patch Panel, 48 Fibres, SC/A, Splice & Patch, Right Hand, 19&21" mounting, all accessories | |
70063243003081L | 96 | LC/APC | Patch only preterm | LH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC/A, Patch only preterm, Left Hand, 19&21" mounting, with tail cable | |
70063243007081L | 96 | LC | Patch only preterm | LH | 1RU UHD Fibre Optic Patch Panel, 96 Fibres, LC, Patch only preterm, Left Hand, 19&21" mounting, with 35m tail cable |
Accessories for standard equipment rack solutions:
Part No. | Description |
825232401081 | Metal Lid to suit 7006 series tray |
835632417KIT | Rear cable gland and tube entry kit - v2. Symmetrical. Includes M20 gland |
835632419KIT | Rear RH entry - tube breakout/protection. Cable entry from right hand side to breakout tubes Left hand entry. Suitable for LH adaptor fibre trays (L product numbers) |
835632420KIT | Rear LH entry - tube breakout/protection. Cable entry from left hand side to breakout tubes Left hand entry. Suitable for RH adaptor fibre trays (R product numbers) |
109X102X10KIT | Splice through kit, RED SC adaptor inserts (splice only applications) |
105 x 49 - L2.5 | Black transport tubing, 6.5 OD, 4.5 ID L=2.5M |
WBT fibre optic infrastructure solutions have elevated cable management to the next level. These high-density solutions can be deployed separately or as an end-to-end solution in a Data Centre or Telecommunications network.
Application includes:
The end to end solution also provides scalability at RU level, with 96F and 144F LC or LC/A deployments.
Can be deployed as an end to end network solution in any Data Centre or Telecommunications network and is compatible with stranded or ultra high density rollable ribbon cable types (864F, 1728F, 3456F, 6912F).
Ultra high density Fibre Termination Panels (FTP’s) or other associated infrastructure can also be successfully deployed as standalone solutions.
LC-LC/A
per RU modules
(splice &/or patch)
in 300mm deep,
single side ODF*
deployment
LC-LC/A
per RU modules
(splice &/or patch)
in 300mm deep,
single side ODF*
deployment
MTP®/MPO
per RU modules
(splice &/or patch)
in 300mm deep,
single side ODF*
deployment
*ODFs can be placed back to back and capacities can be doubled in a 600mm deep footprint