When using Dexgreen closures in the telecommunications network, it is imperative to ensure that correct product handling and installation procedures are followed.
Following the outlined procedures and adhering to the high level of best practice, will ensure compliance in the Telstra and NBN copper access network.
The following information should be followed, which outlines some fundamental Do’s and Don’ts, when using Dexgreen products.
ALWAYS READ INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT
Essential Do’s
Essential Don’ts
Clean and Abrade
Clean and Abrade
Clean all cables and inner walls of closures with wipes provided
Abrade all cables and closure ports circumferentially using abrading strips provided
Re-clean after abrading
Don’t have grease on hands contaminate closure walls
Don’t have grease from cables contaminated closure walls
Contamination
Contamination
Follow work instructions for plastic bag
Use plastic bag to form a tunnel to avoid grease contamination
Don’t have grease on hands contaminate closure walls
Don’t have grease from cables contaminated closure walls
Retain and Separate Cables
Retain and Separate Cables
Use a cable jig to separate cables
Use a cable retainer to retain cables at the base of the closure
Don’t bunch cables together
Don’t allow cables to touch the walls of the closure or each other
Water Block Application
Water Block Application
Cut unit whippings
Fan out conductors
Dispense sealant into centre of fanned out conductors
Don’t bunch conductors
Sealant Storage
Sealant Storage
Store sealant in original packaging until ready to use
Store sealant in cool environment
Don’t heat the sealant in any way to speed up gel time
This will affect performance
Sealant Use
Sealant Use
Always use mixing nozzle
Dispense first 10ms of sealant to equalise the cartridge